Closed-cell doesn't need one — at about 1.5 inches and above it is its own vapor retarder, which removes a separate material and a detail that's often installed wrong. Open-cell is deliberately vapor-permeable, and in a North Texas roofline that permeability is a feature rather than a gap.

Why permeability is intentional

In Climate Zone 3, a roofline assembly benefits from being able to dry. An open-cell roofline lets moisture move through, which means a roof leak stains your ceiling and you find out about it — instead of water tracking along the deck out of sight.

Adding a vapor barrier over open-cell in this application would trap moisture in the assembly. It's the wrong instinct carried over from colder climates.

Where you do want the barrier

AssemblyVapor control
Attic rooflineOpen-cell, permeable — no barrier
Crawl space wallsClosed-cell — is the barrier
Metal buildingClosed-cell — is the barrier
Rim joistsClosed-cell — is the barrier