Closed-cell doesn't need one — at about 1.5 inches and above it is its own vapor retarder, which removes a separate material and a detail that's often installed wrong. Open-cell is deliberately vapor-permeable, and in a North Texas roofline that permeability is a feature rather than a gap.
In Climate Zone 3, a roofline assembly benefits from being able to dry. An open-cell roofline lets moisture move through, which means a roof leak stains your ceiling and you find out about it — instead of water tracking along the deck out of sight.
Adding a vapor barrier over open-cell in this application would trap moisture in the assembly. It's the wrong instinct carried over from colder climates.
| Assembly | Vapor control |
|---|---|
| Attic roofline | Open-cell, permeable — no barrier |
| Crawl space walls | Closed-cell — is the barrier |
| Metal building | Closed-cell — is the barrier |
| Rim joists | Closed-cell — is the barrier |