On a Dallas–Fort Worth attic roofline, typically 5 to 6 inches of open-cell (R-19 to R-21) or 3 to 4 inches of closed-cell (R-19 to R-26). Depth is the most common place cheap installs cut corners, and an underspecified spray is where most sealed-attic moisture problems come from.
| Application | Open-cell | Closed-cell |
|---|---|---|
| Attic roofline | 5–6 in. | 3–4 in. |
| 2×4 exterior wall | 3.5 in. | 2 in. |
| Crawl space walls | Not recommended | 2 in. |
| Metal building | Not recommended | 2–3 in. |
Insufficient depth is the single most common cause of genuine sealed-attic failures. A thin application doesn't keep the assembly above dew point reliably, and it doesn't deliver the R-value the job was sold on.
Ask any bidder for the specified thickness in writing. "Spray foam insulation" without a depth isn't a specification.