That's condensation, not a leak. Warm humid air touches the cold steel panel, drops below its dew point, and the moisture it was holding turns into water that runs down and drips. It happens most on cool nights after warm days, and hard during spring and fall temperature swings.
| Approach | Why it fails |
|---|---|
| Fiberglass batts | Air still reaches the panel; batts get wet and sag |
| Bubble/foil wrap | Addresses radiant heat, not air-to-panel contact |
| Ventilation fans | Keeps introducing more humid outside air |
| Dehumidifier | Fights the symptom forever |
Same problem in every row: none of them stop air from touching cold steel.
Closed-cell spray foam applied directly to the panel. It bonds to the steel so there's no gap for air to reach, and it raises the surface temperature above dew point. Typically 2–3 inches for a DFW building.
It must be closed-cell. Open-cell against metal traps moisture at the panel and makes the problem worse and harder to see.