Your air handler cools air to roughly 55°F. That air then travels through sheet metal and flex duct sitting in an attic at 130–140°F, sometimes for forty or fifty feet, before it reaches your bedroom.
Two things happen on that trip. Heat conducts through the duct wall into the cold air, so it arrives warmer than it left. And wherever the duct leaks, you lose the air entirely — into the attic, which you are not trying to cool.
| Loss type | Typical range | Where it goes |
|---|---|---|
| Duct leakage | 15–30% of conditioned air | Straight into the attic |
| Conduction through duct walls | 5–15% of capacity | Absorbed from hot attic air |
| Combined | 20–40% | Paid for, never delivered |
That's the reason a correctly sized system can still fail to cool a house. The equipment is producing the capacity it was designed to produce; a third of it just never arrives.
Seal and insulate the ducts. Mastic on every joint, proper insulation, disconnected runs repaired. Costs several hundred to about $2,000 and is the right first move if your ducts are visibly leaking or have obvious problems.
Bring the attic inside the envelope. Encapsulating the roofline puts the whole duct system in conditioned space. Leaks still exist but now leak into your house rather than outside it, and conduction nearly disappears because the surrounding air is 75°F rather than 140°F.
If your budget only reaches one of these this year, and your ducts are genuinely leaky, seal the ducts. It's cheaper per unit of benefit and it may be enough on its own.
A blower door and duct blaster test measures this properly. Plenty of DFW HVAC contractors offer it, and it's worth the money before committing to any major work.
Commonly 15–30%, and combined with conduction through duct walls in a hot attic the total loss often reaches 20–40% of what your system produces.
If ducts are visibly leaking or disconnected, seal them first — it's far cheaper. If ducts are sound and the attic is the oven, encapsulation addresses more of the problem at once.
It doesn't repair the leaks, but it makes them far less costly — leaked air ends up inside your conditioned envelope instead of outside it, and conduction losses nearly disappear.
That's the classic duct-loss signature. The longer the run through hot attic air, the more capacity is lost before delivery.
Free, same-day spray foam estimates across Dallas–Fort Worth — from a family-owned crew that's been doing this since 2013.