Spray Foam R-Value: What the Numbers Actually Mean

R-value measures one thing insulation does. Air sealing is the other, and it's the reason fiberglass rarely delivers the number printed on the bag.

What R-value measures — and what it ignores

R-value measures resistance to heat conduction: heat moving through a material. That's genuinely useful, and it's the only number most insulation is sold on.

What it ignores is air movement. A batt of R-38 fiberglass with air leaking around and through it does not deliver R-38 in your house — it delivers whatever's left after the leaks. This is why two attics with identical R-values on paper can have completely different electric bills, and it's the single biggest reason spray foam outperforms its rating in the real world.

R-value is measured in a laboratory on a sealed assembly with no air movement. Your attic is not that.

The numbers, per inch

MaterialR-value per inchAir seal?
Open-cell spray foamR-3.5 – R-3.8Yes
Closed-cell spray foamR-6 – R-7Yes
Fiberglass battR-2.9 – R-3.8No
Blown-in fiberglassR-2.2 – R-2.7No
Blown-in celluloseR-3.2 – R-3.8Partial

Read that table carefully and you'll notice open-cell foam and fiberglass batt are roughly comparable per inch. The difference in performance isn't the R-value — it's the third column.

How many inches you actually need

Dallas–Fort Worth sits in IECC Climate Zone 3. For an encapsulated attic roofline, the depths we typically install:

ApplicationOpen-cellClosed-cell
Attic roofline5–6 in. (R-19 – R-21)3–4 in. (R-19 – R-26)
Exterior walls (2×4)3.5 in. (R-13)2 in. (R-12 – R-14)
Crawl space wallsNot recommended2 in. (R-12 – R-14)
Metal buildingNot recommended2–3 in. (R-13 – R-21)

You'll notice the roofline numbers land below the R-38 often quoted for attic floors. That's not a shortcut — it's a different strategy. An R-38 attic floor leaves the attic itself at 140°F with your ductwork in it. An R-21 sealed roofline brings the whole attic inside your conditioned envelope, which is why it usually outperforms the higher number.

Why chasing R-value alone leads you wrong

If R-value were the whole story, the cheapest path to comfort would be piling more fiberglass into the attic. Plenty of DFW homeowners have done exactly that and called us the following August because nothing changed.

What changed their house was sealing it. A continuous air barrier at a moderate R-value beats a high R-value full of gaps, every summer, in this climate.

Does R-value degrade over time?

Spray foam holds its R-value for the life of the installation — it doesn't sag, settle, or compress. Closed-cell sees a small amount of thermal drift in its first couple of years as the blowing agent stabilizes, which is already accounted for in the aged R-values quoted above.

Fiberglass and blown-in are a different story. They settle, they compress, and rodents move through them. A twenty-year-old blown-in attic in Mesquite is rarely delivering what it did when it was installed.

Straight Answers

Quick answers

What is the R-value of open-cell spray foam?

R-3.5 to R-3.8 per inch. At the 5–6 inches typically installed in a DFW attic roofline, that's about R-19 to R-21 with a full air seal.

What is the R-value of closed-cell spray foam?

R-6 to R-7 per inch — the highest of any insulation we install. Two inches in a wall cavity gets you R-12 to R-14 plus a built-in vapor barrier.

Is a higher R-value always better?

No. A sealed R-21 roofline routinely outperforms an unsealed R-38 attic floor in this climate, because it removes the 140°F attic and the duct losses along with it.

How thick should spray foam be in a Texas attic?

Typically 5–6 inches of open-cell or 3–4 inches of closed-cell on the underside of the roof deck. Exact depth depends on the assembly and how the attic is used.